Supported Generator Types
• Residential single-phase generators
• Automatic or manual start
• Systems ≤20 kW
Installation Notes
• Generator conductors land in designated terminals
• Install generator CTs if required
• Auto-start wiring uses low-voltage terminals only
• Neutral and grounding scheme must be verified
Verification
• Generator starts during outage simulation
• Loads transition correctly
• Priority circuits behave as expected